Single Zone Air Conditioner
SVC MANUAL(General)
CAUTION
Before Servicing the unit, read the safety
precautions in General SVC manual.
Only for authorized service personnel.
960-914-06
Vedere la pagina 0
1 2 3 4 5 6 ... 89 90

Sommario

Pagina 1 - SVC MANUAL(General)

Single Zone Air ConditionerSVC MANUAL(General)CAUTIONBefore Servicing the unit, read the safety precautions in General SVC manual.Only for authorized

Pagina 2 - TABLE OF CONTENTS

- 10 -Only for training and service purposesPart 2 Functions & Controls1. List of Functions & Accessory ...

Pagina 3 - Part 1 General Information

- 11 -Only for training and service purposes1. List of Functions & Accessory1. Ceiling Concealed Duct IndoorCategory Functions RemarkAir flowAir s

Pagina 4 - 1. Safety Precautions

- 12 -Only for training and service purposesAir supply outlet 4Airflow direction control(left & right) -Airflow direction control(up & down) A

Pagina 5

- 13 -Only for training and service purposes3. OutdoorCategory FunctionsMR24UY3J MR36UY3JReliabilityDefrost / Deicing O OHigh pressure switch X XLow p

Pagina 6 - 1.2 Inspections after Repair

- 14 -Only for training and service purposes2. Air flow2.1 Auto swing (left & right)RightLeft110° ~ 120°OpenClose110° ~ 120°Mode2Mode3Mode4Mode5Mo

Pagina 7 - 2. Model Line Up

- 15 -Only for training and service purposesNOTE: Some Models are different by swing width and swing pattern.2.4 Air flow step• Indoor fan motor contr

Pagina 8

- 16 -Only for training and service purposes3.Reserved (Blank)

Pagina 9 - 2.3 Nomenclature

- 17 -Only for training and service purposes4.1 E.S.P. (External Static Pressure) Setting (DUCT)4. Installation FunctionsThis is the function that dec

Pagina 10

- 18 -Only for training and service purposesE.S.P. setting value (reference)[ Notes ] 1. To get the desired Airflow & E.S.P. combination from the

Pagina 11

- 19 -Only for training and service purposes4.2 E.S.P. (External Static Pressure) Setting (Cassette)Function Code PressurePress button for 4 sec

Pagina 12

- 2 -Only for training and service purposesAir Conditioner Service ManualTABLE OF CONTENTSPart 1 General Information ...

Pagina 13 - 3. Outdoor

- 20 -Only for training and service purposesIf entering into ESP setup mode by using button, it indicates as the picture below.2Select ESP f

Pagina 14 - 2. Air flow

- 21 -Only for training and service purposes5.1 Hot start• When heating is started, the indoor fan is stopped or very slow to prevent the cold air car

Pagina 15 - 2.7 Swirl wind Swing

- 22 -Only for training and service purposes6.1 Cooling & heating Operations6.1.1 Cooling Mode• Operating frequency of compressor depends on the

Pagina 16 - Reserved (Blank)

- 23 -Only for training and service purposes6.4 Auto restart Operation• Whenever there is electricity failure to the unit, and after resumption of the

Pagina 17 - 4. Installation Functions

- 24 -Only for training and service purposes6.5 Child Lock FunctionIt is the function to use preventing children or others from careless using.TEMPFAN

Pagina 18 - [ Notes ]

- 25 -Only for training and service purposes6.6 Forced operation• To operate the appliance by force in case when the remote control is lost, the force

Pagina 19 - Function Code Pressure

- 26 -Only for training and service purposes6.7 Group Control1. When installing more than 2 units of air conditioner toone wired remote controller, pl

Pagina 20 - ESP step

- 27 -Only for training and service purposes6.8 Sleep Timer Operation• When the sleep time is reached after <1,2,3,4,5,6,7,0(cancel) hr> is inpu

Pagina 21 - 5. Reliability

- 28 -Only for training and service purposes6.10 Weekly ProgramPlease move to 'weekly' by repeatedly pressing reservation button. 'Week

Pagina 22 - 6.1.2 Heating Mode

- 29 -Only for training and service purposesPlease move to 'AM/PM' setup part of turning off by using button.- AM/PM setup is identical

Pagina 23 - 6.2 Auto cleaning operation

- 3 -Only for training and service purposes1. Safety Precautions ...

Pagina 24 - 6.5 Child Lock Function

- 30 -Only for training and service purposes6.11 Two Thermistor ControlTEMPFANSPEEDOPERMODEWhen pressing the button and button simultaneou

Pagina 25 - 6.6 Forced operation

- 31 -Only for training and service purposesFunction Code Thermistor settingSet Thermistor value by pressing button. (01: Remote Controller, 02: Indoo

Pagina 26 - 6.7 Group Control

- 32 -Only for training and service purposes7.1 Low Ambient control• This Function is for cooling operating in outdoor low temperature .• If outdoor

Pagina 27 - 6.9 Timer(On/Off)

- 33 -Only for training and service purposes

Pagina 28 - 6.10 Weekly Program

- 34 -Only for training and service purposes

Pagina 29

- 35 -Only for training and service purposesPart 3 Basic Control1. Normal operation...

Pagina 30 - 6.11 Two Thermistor Control

- 36 -Only for training and service purposesBasic principle is to control the rpm of the motor by changing the working frequency of the compressor.Thr

Pagina 31

- 37 -Only for training and service purposesPart 4 Trouble Shooting 1. Self-diagnosis Function...

Pagina 32 - 7. Special Function

- 38 -Only for training and service purposes1. Self-diagnosis FunctionEx) Error 03 (Remote controller error)1.1 Error Indicator (Indoor)3 Times 3 Time

Pagina 33

- 39 -Only for training and service purposes1.2 Error Indicator (Outdoor)If abnormal voltage is supplied, the protection circuits will turn off the pr

Pagina 34

- 4 -Only for training and service purposes1. Safety Precautions 1.1 Cautions in Repair To prevent injury to the user or other people and property dam

Pagina 35 - Part 3 Basic Control

- 40 -Only for training and service purposes2. Pump DownSetting Procedure1) Set the Dip Switch as follow after shutting the power source down.2) Reset

Pagina 36 - 2. Compressor control

- 41 -Only for training and service purposes• Procedure(1) Connect the vacuum pump to the center hoseof charge set center hose (2) Evacuation for appr

Pagina 37 - Part 4 Trouble Shooting

- 42 -Only for training and service purposesLoChargingcylinder Outdoor unitIndoor unitLiquid sideGas sideOpen3-Wayvalve3-WayvalveOPENOpenCheck valve(1

Pagina 38 - 1. Self-diagnosis Function

- 43 -Only for training and service purposesTrouble analysis1. Check temperature difference between intake and discharge air, and check for the operat

Pagina 39 - 1.2 Error Indicator (Outdoor)

- 44 -Only for training and service purposes6.1 The Product doesn’t operate at allThe operation check of the Indoor PCB AssemblyProcedure1) The input

Pagina 40 - 2. Pump Down

- 45 -Only for training and service purposes6.2 The Product doesn't operate with the remote controllerTurn on the main powerYesNoA "Beeping

Pagina 41 - Vacuum pump

- 46 -Only for training and service purposesTurn on the main power.When in air circulation mode, compressor/outdoor fan is stopped.Turn off main power

Pagina 42

- 47 -Only for training and service purposes6.4 When indoor Fan does not operate.Check the SSR high speed operation by remote control.(the Indoor Fan

Pagina 43 - 5. Cycle Part

- 48 -Only for training and service purposes• Confirm that the vertical louver is normally geared with the shaft of Stepping Motor.• If the regular to

Pagina 44 - 6. Electronic Parts

- 49 -Only for training and service purposes6.6 Troubleshooting Indoor ErrorCheck Point1. Unplug the sensor on Indoor unit PCB.2. Estimate the resist

Pagina 45

- 5 -Only for training and service purposesDo not turn on the breaker under condition that front panel and cabinet areremoved.Be sure to earth the air

Pagina 46

- 50 -Only for training and service purposesCheck the Volt.Indoor UnitV12Vdc12V(RD)S(YL)S(YL)GND(BK)Check the Volt.Wired R/CV12Vdc12V(RD)GND(BK)Check

Pagina 47

- 51 -Only for training and service purposesCheck the wire connection (Open, Soldered poorly)❊ Drain pump check Check drain tube installationIs it nor

Pagina 48

- 52 -Only for training and service purposesChange Option PCBCheck the the connection port.Is it normal ?YesNo Correct connectionCheck Flow Chart (CH0

Pagina 49 - Check Point

- 53 -Only for training and service purposes10Indoor BLDC Fan MotorLockThe Fan is not operatedproperlyCheck the Indoor fan lockingDisplaycodeTitle Cau

Pagina 50

- 54 -Only for training and service purposesIs the connection of GND,GND1,GND2, correctly connected?Change PCB❊ CH05 is displayed at indoor unit,

Pagina 51

- 55 -Only for training and service purposes6.7 Troubleshooting Outdoor Error21DC PEAK(IPM Fault)• Instant over current• Over Rated current• Poor insu

Pagina 52 - Check Flow Chart (CH09)

- 56 -Only for training and service purposesn AUUW24GD2 [MR24UY3J]Y^ Y] Y\ Y[ YZ YY YXw ~ } | u u uzwtZLED02MLED01MUVW1. Wait until inverter PCB DC

Pagina 53

- 57 -Only for training and service purposesn AUUW36GD2 [MR36UY3J]AC(N)-BLUEAC(L)-BROWNUVWU,V,W CONNECTOR1. Wait until inverter PCB DC voltage is disc

Pagina 54 - Check Flow Chart

- 58 -Only for training and service purposes22Max. C/T• Input Over Current• Malfunction of compressor• Blocking of pipe• Low voltage input• Refrigeran

Pagina 55 - Copper pipe

- 59 -Only for training and service purposesCheck Point1. Check the power source.(230V ±15%)2. Check the fan operation is right.3. Check the current.4

Pagina 56 - U, V, W ‘ R S T

- 6 -Only for training and service purposes1.2 Inspections after RepairCheck to see if the parts are mounted correctly and wires are connected.Imprope

Pagina 57

- 60 -Only for training and service purposes23DC Link High / Low Volt• DC Link Voltage isabove 420Vdc• DC Link Voltage isbelow 140Vdc• Check CN_(L), C

Pagina 58

- 61 -Only for training and service purposesCheck Point1. Check the WCN_P(L),P(N) Connection condition at the Main PCB.(Refer to outdoor wiring diagra

Pagina 59

- 62 -Only for training and service purposesVdc AUUW36GD2 [MR36UY3J]PGND

Pagina 60

- 63 -Only for training and service purposesCheck Point1. Check the Input Voltage (L1- L2 ‘ 230V±10%)2. Check Input Voltage Sensor output voltage (2.5

Pagina 61

- 64 -Only for training and service purposes< Inverter PCB> < Input Voltage Sensing Check Point > AUUW24GD2 [MR24UY3J]AUUW36GD2 [MR36UY3J

Pagina 62 - AUUW36GD2 [MR36UY3J]

- 65 -Only for training and service purposes26DC CompressorPosition• Compressor Starting fail error• Check the connection of comp wire “U,V,W”• Malfu

Pagina 63

- 66 -Only for training and service purposes AUUW36GD2 [MR36UY3J]UWVGND

Pagina 64

- 67 -Only for training and service purposes27AC Input Instant overCurrent Error Inverter PCB input current is over100A(peak)for 2us1. Overload operat

Pagina 65 - * AUUW24GD2 [MR24UY3J]

- 68 -Only for training and service purposes<Short Check Point> <Short Check Point> * AUUW24GD2 [MR24UY3J]* AUUW36GD2 [MR36UY3J]

Pagina 66

- 69 -Only for training and service purposes29Inverter compressor overcurrentInverter compressor inputcurrent is over 30A1. Overload operation (Pipe c

Pagina 67

- 7 -Only for training and service purposesCategoryChassisNameCapacity Index[kBtu/h]24 36CeilingConcealedDuctHighStaticPressureBGBRCeilingCassette4way

Pagina 68 - * AUUW36GD2 [MR36UY3J]

- 70 -Only for training and service purposesDisplaycodeTitle Cause of error Check point & Normal condition32High temperature inDischarge pipe of t

Pagina 69

- 71 -Only for training and service purposesDisplaycodeTitle Cause of error Check point & Normal condition35 Low Presser ErrorExcessive decrease o

Pagina 70 - (RED 4Pin Connector)

- 72 -Only for training and service purposes39Transmission ErrorBetween (PFC Micom ’INV Micom)Communication ErrorBetween PFC Micomand INV Micom.1. Mic

Pagina 71

- 73 -Only for training and service purposesCheck Point1. Check the Input Voltage (L1- L2 ‘ 230V±10%)2. Check Input Voltage Sensor output voltage (2.5

Pagina 72

- 74 -Only for training and service purposes AUUW36GD2 [MR36UY3J] AUUW24GD2 [MR24UY3J]IN/IGND<CT Sensing Check Point> BlackRedVdc123Vdc<CT Se

Pagina 73

- 75 -Only for training and service purposesDisplaycodeTitle Cause of error Check point & Normal condition41 D-pipe sensor (Inverter)• Open / Shor

Pagina 74

- 76 -Only for training and service purposesDisplaycodeTitle Cause of error Check point & Normal condition43Sensor error of highpressureAbnormal v

Pagina 75

- 77 -Only for training and service purposes53TitleCommunication(Indoor ’ Outdoor)• Communication poorly• Power input AC 230V. (Outdoor, Indoor)• The

Pagina 76

- 78 -Only for training and service purposes60Inverter PCB & Main EEPROM check sum errorEEPROM Access errorand Check SUM error1. EEPROM contact de

Pagina 77

- 79 -Only for training and service purposes* AUUW36GD2 [MR36UY3J]EEPROM

Pagina 78

- 8 -Only for training and service purposes3.Blank

Pagina 79

- 80 -Only for training and service purposesDisplaycodeTitle Cause of error Check point & Normal condition61High temperature in out-door Cond. Pip

Pagina 80 - Recheck power and

- 81 -Only for training and service purposes62Heatsink High errorInverter PCB heatsinktemperature is over 85°C1. ODU fan locking2. Heatsink assembly o

Pagina 81

- 82 -Only for training and service purposes* AUUW24GD2 [MR24UY3J]* AUUW36GD2 [MR36UY3J]ΩPFCM: Measuring resistance between No.19,20 pin

Pagina 82 - Measuring resistance

- 83 -Only for training and service purposes65Heatsink Sensor errorInverter PCB heatsinksensor is open or short1. ODU fan locking2. Heatsink assembly

Pagina 83

- 84 -Only for training and service purposes* AUUW24GD2 [MR24UY3J]* AUUW36GD2 [MR36UY3J]ΩPFCM: Measuring resistance between No.19,20 pin

Pagina 84

- 85 -Only for training and service purposes67Fan Lock ErrorFan RPM is 10RPM orless for 5 sec. when ODUfan starts or 40 RPM orless after fan starting.

Pagina 85

- 86 -Only for training and service purposes<Main PCB> AUUW36GD2 [MR36UY3J]AUUW24GD2 [MR24UY3J]TesterFan motorconnectorCheck voltage betwen1pin

Pagina 86 - AUUW24GD2 [MR24UY3J]

- 87 -Only for training and service purposes73AC input instant over cur-rent error (Matter of software)Inverter PCB input powercurrent is over 48A(pea

Pagina 87

- 88 -Only for training and service purposes< Input Power Source Check Point > < Main PCB wiring Check Point > NN LN L < Noise Filter

Pagina 88

- 89 -Only for training and service purposesLNNLLLNNNLNLLN< Input Power Source Check Point > AUUW36GD2 [MR36UY3J]LNNLLLNNNLNLLN< Input Power

Pagina 89

- 9 -Only for training and service purposes2.3 NomenclatureM RH 36 D Y 3 J M Installation Type M : Multi ZoneMarketing Model Electrical rating 1

Commenti su questo manuale

Nessun commento