Friedrich CP05N10A Manuale Utente

Navigare online o scaricare Manuale Utente per Condizionatori Friedrich CP05N10A. Friedrich CP05N10A User Manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa

Sommario

Pagina 1 - Service and Parts

Room Air ConditionerService and PartsManualCP05 Svc Parts 2010 (05/10)CP05N10A115 Volts

Pagina 2 - CONTENTS

2.4.2 EVAPORATOR1. Remove the cabinet.2. Discharge the refrigerant by using a refrigerantrecovery system.3. Remove the upper air guide . (Refer to Se

Pagina 3 - 1. PREFACE

—10—Equipment needed: Vacuum pump, charging cylinder, manifold gauge, brazing equipment, pinch-off tool capableof making a vapor proof seal, leak dete

Pagina 4 - 1.3 LOCATIONS OF CONTROLS

—11—2.4.4 ELECTRICAL DATAUSE OF EXTENSION CORDSBecause of potential safety hazards, we strongly discourage the use of an extension cord. However, if y

Pagina 5 - 2. DISASSEMBLY INSTRUCTIONS

—12—3.2 PIPING SYSTEMFollowing is a brief description of the important components and their function in what is called the refrigerationsystem. Refere

Pagina 6 - 2.2 AIR HANDLING PARTS

—13—3.3 TROUBLESHOOTING GUIDE In general, possible trouble is classified in two kinds. The one is called Starting Failure which is caused by an electr

Pagina 7 - 2.3 ELECTRICAL PARTS

—14—Fails to Start Improper thermostat settingLoose terminal connectionImproper wiring Check voltage power source. Drop of power voltage. Capacitor ch

Pagina 8 - 2.3.5 CONTROL BOARD

COMPLAINT CAUSE REMEDY Fan motor will not run. No power Check voltage at outlet. Correct if none. Power supply cord Check voltage to electronic con

Pagina 9 - 2.4 REFRIGERANT CYCLE

—16—&203/$,17 &$86( 5(0('<)DQPRWRUQRLVH )DQEODGH ,IFUDFNHGRXWRIEDODQFHRUSDUWLDOO\PLVVLQJUHSODFHLW%ORZHU wheel ,

Pagina 10 - 2.4.3 CAPILLARY TUBE

—17—COMPLAINT CAUSE REMEDY Compressor cycles on Fan motor If not running, determine the cause. Replace if overload. required. Condenser air flow R

Pagina 11

—18—4. CIRCUIT DIAGRAM(SMPS) 250V/T2A(250V/T3.15A)MEZ62420702WH(BL)LOCATIONPART NO Q'TYNO.CP05N10A PER SET1 POWER CORD ASSY67300020 12FAN MOTOR

Pagina 12 - 3. TROUBLESHOOTING GUIDE

—2—CONTENTS1. PREFACE ...

Pagina 13 - 3.2 PIPING SYSTEM

²19²(;3/2'('9,(:352390-2::$0

Pagina 14 - 3.3 TROUBLESHOOTING GUIDE

—20—LocNo DESCRIPTION CP05N10A130410 Base Assembly,Weld67302931130910 Cabinet67303719135312 Grille Assembly,Front67306008135303 Grille,Inlet6730610714

Pagina 15

Post Office Box 1540 • 4200 N. Pan Am Expressway • San Antonio, Texas 78295-1540• (210) 357-4400 • FAX (210) 357-4490FRIEDRICH AIR CONDITIONING CO.Vis

Pagina 16

1. PREFACEThis service manual provides various service information, including the mechanical and electrical parts, etc. This room air conditioner was

Pagina 17

—3—1.3 LOCATIONS OF CONTROLS MONEY SAVER2The fan stops when the compressor stops cooling.• Approximately every 3 minutes the fan will turn on and samp

Pagina 18

—4—2. DISASSEMBLY INSTRUCTIONS2.1 MECHANICAL PARTS2.1.1 FRONT GRILLE 1. Pull the inlet grille forward.2. Remove the screw securing the Front Grille. (

Pagina 19 - 4. CIRCUIT DIAGRAM

—5—2.2 AIR HANDLING PARTS 2.2.1 AIR GUIDE UPPER 1. Disconnect the unit from the power source.2. Remove the front grille. (Refer to Section 2.1.1)3.

Pagina 20 - (;3/2'('9,(:

—6—2.2.3 MOTOR1. Disconnect the unit from the power source.2. Remove the front grille. (Refer to Section 2.1.1)3. Remove the cabinet. (Refer to Sectio

Pagina 21

—7—2.3.2 COMPRESSOR 1. Remove the front grille and cabinet. (Refer to Section 2.1) 2. Discharge the refrigerant by using a refrigerantrecovery system.

Pagina 22

—8—2.3.6 POWER CORD1. Disconnect the unit from source of power.2. Remove the front grille. (Refer to Section 2.1.1)3. Remove the cabinet. (Refer to Se